KCST2616
Update time:2016-07-01 22:27:32Click times:956
Related introduction
Colposcopy technology parameters:
Lens technology requirements:
1, image sensors: 1/4'Super Had CCD
2, image pixel: 16000000 pixels
3, the scanning system: NTSC standard 525 lines, 30 frame / sec
PAL standard 625 lines, 25 frame / sec
4, the shot level resolution: 480 TV line
5, automatic focusing distance of 200mm ~ 300 mm, with automatic focusing state prompting function
6, the lens:: optical 1 ~ 18 times optical zoom lens, the number 19 ~ 28 times, continuous stepless amplification
7, electronic shutter control: 1/50 ~ 1/10000
8, Gamma: 0.45
9, field of view angle: 48 ° -2.7 ° (WIDE) (TELE)
10, the minimum illumination: 1.0Lux
11, zoom speed: 3 SEC mode/6 SEC mode
12, video output standard: 1VP-P75 ohms mixed
13, backlight compensation: on / off
14, EV compensation: -10.5DB - 10.5DB
15, vision range than 10mm ~ 60mm
16, the depth of field ranges from 5mm to 120mm
17, lens automatic white balance adjustment
18, the life of the light source is ≥ 50000 hours, illumination is greater than or equal to 2000Lux
19, based on the key control electronic green three level filter technology
20, based on the timing button control of acetic acid to reflect or iodine staining test control technology (display and record the image), the need to mention
Samples for graphic report
21, to observe the inspection image magnification show, can provide samples of picture and text report
22, the image zoom, white, green, timing, freezing and other functions integrated in the palm type control system, the real
Palm type control
23, the lifting upright bracket, desktop computer.
2 colposcopy workstation performance requirements:
2.1, work platform truck disassemble packing, 17 "LCD
2.2, support of real-time display, image acquisition, freeze, store and print
2.3, can carry out dynamic video and movie playback on the observation check image
Case base management mode 2.4, digital:
2.4.1, the real patient information system based on database management, can provide the database name
2.4.2, can store up to 1000000 images of the data, and can be the case any call, add, delete
2.4.3, can be a variety of queries on the patient information conveniently, and statistical analysis of patient data
Color graphic print 2.4.4, support more than two kinds of patient reported, can provide graphic report users
2.4.5, may be required to design and print the save, print the report users have their own style. To print the report
Illustrated, with a photo quality printing.
2.5, support LEEP operation report printing function
Comparison of 2.6, support the patient information analysis function
2.7, support RCI analysis, can provide samples of picture and text report
2.8, support the foot switch control diagram with the mouse control mining map
2.9, with the DICOM3.0 image data exchange interface, support network function, provide the use of hospital information
2.10, the machine installed anti misoperation automatic recovery system, once the abnormal situation, can be immediately restored to the initial system.
State
The storage environment conditions
1, power consumption: 1.5W-2.5W
2, positive and negative control: on / off
3, the working environment temperature: -10 ° C - 60 ° C
4, storage environment temperature: 30 ° C - 80 ° C
5, the power supply DC: 9V-12V
6, weight: 55Kg
7, size: 118 (L) X 60 (W) X75 (H)